INTIEAUnited States · 2014 Oregon Energy Efficiency Specialty CodePolicyIn force

2014 Oregon Energy Efficiency Specialty Code

CONTINUOUS INSULATION. Insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior or exterior or is integral to any opaque surface of the building. RESIDENTIAL BUILDING. For this…

Last changed 8 years ago.

Extracted view for reading · Original for compliance evidence

Lifecycle

  1. Effective
  2. Last change

Country / jurisdiction: United States · Year: 2014 · Status: In force · Level: State/Provincial · Type: Voluntary

CONTINUOUS INSULATION. Insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior or exterior or is integral to any opaque surface of the building.

RESIDENTIAL BUILDING. For this code, includes R-3 buildings regulated under the Residential Code: one- and two-family dwellings and townhouses.

BUILDING ENVELOPE REQUIREMENTS:

Insulation and fenestration criteria. The building thermal envelope opaque assemblies shall meet the requirements of Table 502.1.1 and Section 502.2 Tables 502.2(1). Fenestration shall meet the requirements of Section 502.3.

Commercial buildings or portions of commercial buildings enclosing occupancies other than Group R shall use the R-values from the “All other” column of Table 502.2(1) 502.1.1. Buildings with a vertical fenestration area or skylight area that exceeds that allowed in Table 502.3 shall comply with Section 502.1.3, Simplified tradeoff approach or Section 506.1, Whole Building Approach.

U-factor alternative. Opaque assemblies with a U-factor, C-factor, or F-factor equal or less than that specified in Table 502.1.2 shall be permitted as an alternative to the R-value in Table 502.2(1) 502.1.1. Commercial buildings or portions of commercial buildings enclosing Group R occupancies shall use the U-factor, C-factor, or F-factor from the “Group R” column of Table 502.1.2. Commercial buildings or portions of commercial buildings enclosing occupancies other than Group R shall use the Ufactor, C-factor or F-factor from the “All other” column of Table 502.1.2.

Official source: http://ecodes.biz/ecodes_support/free_resources/Oregon/14_Energy/14_OREnergy_main.html

Source

https://www.iea.org/policies/7123

Canonical document at the regulator. Always cite this URL — not the Vantage detail page — in compliance evidence.

Related in International

INTEnergy Newsoilprice:oilprice-article-45339NewsIn force

Egypt’s LNG Comeback Is Set to Start in Cyprus

Egypt’s gas sector is running short of domestic gas just as Cyprus prepares to become a producer. The recently approved Cronos project offshore Cyprus (expected to deliver up to 2.8 million tonnes per year of LNG from 2028) offers a three-way bargain. Cyprus gains an export route it cannot economically build alone; Egypt secures feedstock for infrastructure increasingly constrained by falling domestic production, and Europe gains another non-Russian source. The logic is compelling, but technical, commercial and geopolitical risks could still…

23 hours ago
INTEnergy Newsoilprice:oilprice-article-45338NewsIn force

East Africa’s Oil Rivalry Spurs Multi-Billion-Dollar Projects Across The Region

Last month, we reported that Nigerian billionaire and Africa’s richest man, Aliko Dangote, has agreed to build a $17 billion (Ksh2.2 trillion), 700,000-barrel-per-day refinery on Kenya’s Lamu Island that would process crude not only for Kenya but also its neighbors such as Uganda, Rwanda, Burundi, South Sudan and the DRC. The giant refinery--Africa’s second largest refinery behind only Nigeria’s Dangote refinery--would easily exceed East Africa’s current refined fuel demand of roughly 450,000 bpd, leaving room to supply…

1 day ago
INTEnergy Newsoilprice:oilprice-article-45337NewsIn force

DoE Begins Tests for Fracked Geothermal

The Trump administration is no friend of wind and solar. Axed subsidies and project suspensions have been the attitude towards those alternative forms of energy. Geothermal, however, is something else. The current Department of Energy is very much for it. In fact, it is so much for it that it funded an experiment that would show whether fracking technology could be used to generate geothermal anywhere in the world. Geothermal energy is, simply put, heat. It is heat that is generated from the decay of radioactive elements in the planet’s mantle.…

1 day ago
INTEnergy Newsoilprice:oilprice-article-45336NewsIn force

Europe Heads Into Winter With Gas Storage at a Two-Decade Low

Europe is heading for the winter with one of the lowest levels of gas in storage in the past two decades as the war in the Middle East crippled LNG supply from Qatar, sent gas and LNG prices in Europe and Asia skyrocketing, and intensified competition for the shrunk pool of readily available global LNG cargoes. A perfect storm of elevated demand for filling depleted storage and electricity during the summer heatwaves, and slashed global LNG supply with Qatar’s cargoes trapped behind the Strait of Hormuz have pushed European benchmark prices…

1 day ago
INTEnergy Newsrigzone:https://www.rigzone.com/news/wire/oil_rises_as_iran_deal_hopes_fade-27-aug-2026-184478-article/?rss=trueNewsIn force

Oil Rises as Iran Deal Hopes Fade

Oil rose as doubts grew over a broader US-Iran agreement.

1 day ago