INTIEAUnited States · 2015 IECC with Amendments - Residential Building code (Illinois)PolicyIn force

2015 IECC with Amendments - Residential Building code (Illinois)

Compliance Projects shall comply with one of the following: 1. Sections R401 through R404. 2. Section R405 and the provisions of Sections R401 through R404 labelled "Mandatory." 3. An energy rating index (ERI) approach in Section R406. Building Thermal Envelope The building…

Last changed 8 years ago.

Extracted view for reading · Original for compliance evidence

Lifecycle

  1. Effective
  2. Last change

Country / jurisdiction: United States · Year: 2016 · Status: In force · Level: State/Provincial · Type: Voluntary

Compliance

Projects shall comply with one of the following:

1. Sections R401 through R404.

2. Section R405 and the provisions of Sections R401 through R404 labelled "Mandatory."

3. An energy rating index (ERI) approach in Section R406.

Building Thermal Envelope

The building thermal envelope shall meet the requirements of Sections R402.1.1 through R402.1.5.

Specific Insulation Requirements (Prescriptive)

In addition to the requirements of Section R402.1, insulation shall meet the specific requirements of Sections R402.2.1 through R402.2.13.

Fenestration (Prescriptive)

In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.5.

Air Leakage (Mandatory)

The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.4.

Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.

Service Hot Water Systems

Energy conservation measures for service hot water systems shall be in accordance with Sections R403.5.1 through R403.5.4.

Lighting Equipment (Mandatory)

Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps.

Energy Rating Index

The Energy Rating Index (ERI) shall be a numerical integer value that is based on a linear scale constructed such that the ERI reference design has an Index value of 100 and a residential building that uses no net purchased energy has an Index value of 0. Each integer value on the scale shall represent a 1-percent change in the total energy use of the rated design relative to the total energy use of the ERI reference design. The ERI shall consider all energy used in the residential building.

Existing Buildings

Additions, alterations, or repairs to an existing building, building system or portion thereof shall comply with Section R502, R503 or R504. Unaltered portions of the existing building or building supply system shall not be required to comply with this code.

Except as specified in this chapter, this code shall not be used to require the removal, alteration or abandonment of, nor prevent the continued use and maintenance of, an existing building or building system lawfully in existence at the time of adoption of this code.

Amendements below include but not limited to:

Tables R402.1.2 Insulation/Fenestration and R402.1.4

Amended as follows –

Climate Zone 4: SHGC not required, 2015 IECC requires 0.40

Climate Zone 5: Basement Wall Insulation 10/13, 2015 IECC requires 15/19

Basement Wall Total U-factor 0.059, 2015 IECC requires 0.050

R402.2.9 Basement walls. Walls associated with conditioned basements shall be insulated from the top of the basement wall down to 10 feet (3048 mm) below grade or to within six-inches (152 mm) of the basement floor, whichever is less. Walls associated with unconditioned basements shall meet this requirement unless the floor overhead is insulated in accordance with Sections R402.1.2 and R402.2.8.

Official source: https://codes.iccsafe.org/content/IECC2015

Source

https://www.iea.org/policies/7173

Canonical document at the regulator. Always cite this URL — not the Vantage detail page — in compliance evidence.

Related in International

INTEnergy Newsoilprice:oilprice-article-45339NewsIn force

Egypt’s LNG Comeback Is Set to Start in Cyprus

Egypt’s gas sector is running short of domestic gas just as Cyprus prepares to become a producer. The recently approved Cronos project offshore Cyprus (expected to deliver up to 2.8 million tonnes per year of LNG from 2028) offers a three-way bargain. Cyprus gains an export route it cannot economically build alone; Egypt secures feedstock for infrastructure increasingly constrained by falling domestic production, and Europe gains another non-Russian source. The logic is compelling, but technical, commercial and geopolitical risks could still…

23 hours ago
INTEnergy Newsoilprice:oilprice-article-45338NewsIn force

East Africa’s Oil Rivalry Spurs Multi-Billion-Dollar Projects Across The Region

Last month, we reported that Nigerian billionaire and Africa’s richest man, Aliko Dangote, has agreed to build a $17 billion (Ksh2.2 trillion), 700,000-barrel-per-day refinery on Kenya’s Lamu Island that would process crude not only for Kenya but also its neighbors such as Uganda, Rwanda, Burundi, South Sudan and the DRC. The giant refinery--Africa’s second largest refinery behind only Nigeria’s Dangote refinery--would easily exceed East Africa’s current refined fuel demand of roughly 450,000 bpd, leaving room to supply…

24 hours ago
INTEnergy Newsoilprice:oilprice-article-45337NewsIn force

DoE Begins Tests for Fracked Geothermal

The Trump administration is no friend of wind and solar. Axed subsidies and project suspensions have been the attitude towards those alternative forms of energy. Geothermal, however, is something else. The current Department of Energy is very much for it. In fact, it is so much for it that it funded an experiment that would show whether fracking technology could be used to generate geothermal anywhere in the world. Geothermal energy is, simply put, heat. It is heat that is generated from the decay of radioactive elements in the planet’s mantle.…

1 day ago
INTEnergy Newsoilprice:oilprice-article-45336NewsIn force

Europe Heads Into Winter With Gas Storage at a Two-Decade Low

Europe is heading for the winter with one of the lowest levels of gas in storage in the past two decades as the war in the Middle East crippled LNG supply from Qatar, sent gas and LNG prices in Europe and Asia skyrocketing, and intensified competition for the shrunk pool of readily available global LNG cargoes. A perfect storm of elevated demand for filling depleted storage and electricity during the summer heatwaves, and slashed global LNG supply with Qatar’s cargoes trapped behind the Strait of Hormuz have pushed European benchmark prices…

1 day ago
INTEnergy Newsrigzone:https://www.rigzone.com/news/wire/oil_rises_as_iran_deal_hopes_fade-27-aug-2026-184478-article/?rss=trueNewsIn force

Oil Rises as Iran Deal Hopes Fade

Oil rose as doubts grew over a broader US-Iran agreement.

1 day ago